Radius BZ1 Area Monitor

When it comes to choosing equipment to protect your worksite from hazardous gases, rely on the Radius™ BZ1 Area Monitor. No other area monitor protects your workers longer in the field with less setup, user training, and time in the shop.

  • Detect up to seven gases using 15 sensor options including PID
  • Longest running area monitor with a typical run time of 7 days (168 hours)
  • Audible alarms sound at 108 dB at 1 m to cut through high-noise environments
  • LENS™ Wireless networks share alarms and data with no setup or infrastructure
  • Largest display of any area monitor on the market
  • Customizable alarm action messages such as "EVACUATE" or "VENTILATE"
  • DualSense ® Technology increases worker safety by using two sensors to detect the same gas
  • iNet ® and DSX™ Docking Station ready

Запросить дополнительную информацию

Radius just works, no questions asked, so your teams can focus on what's important and be confident that their area monitors are ready for whatever comes their way.

Deploy Whenever and Wherever: Whether setting up a perimeter, or monitoring leaks or confined spaces, the Radius BZ1 allows for flexible deployments to create buffers between workers and gas hazards.

Get the Message Loud and Clear: Loud audible alarms and different colored strobes for gas and non-gas events ensure workers not only know when the instrument is alarming, but why.

React With Confidence: Identify gases and alarms from a safe distance, and read critical safety messages such as "EVACUATE" or "VENTILATE," thanks to a display that is three times larger than its nearest competitors'.

Know What is Happening Without Approaching: Create wireless networks out of the box and receive real-time gas readings from other instruments thanks to LENS Wireless and its automatic, peer-to-peer mesh network.

Spend Less Time Managing Your Instruments: Your instruments will spend more time in the field and less time in the shop thanks to a unique modular design, the DSX™ Docking Station, and patented DualSense ® Technology.

  1. Select the Sensors   Насос Беспроводной Monitor
    Radius BZ1 - LEL (Pentane), CO, H2S, O2       BZ1-K123000x0y
    Radius BZ1 - LEL (Pentane), CO, H2S, O2      ✔   BZ1-K123000x1y
    Radius BZ1 - LEL (Pentane), CO, H2S, O2    ✔     BZ1-K123001x0y
    Radius BZ1 - LEL (Pentane), CO, H2S, O2      ✔    ✔   BZ1-K123001x1y
    Radius BZ1 - LEL (Pentane), CO, H2S, O2, SO2       BZ1-K123500x0y
    Radius BZ1 - LEL (Pentane), CO, H2S, O2, SO2      ✔   BZ1-K123500x1y
    Radius BZ1 - LEL (Pentane), CO, H2S, O2, SO2    ✔     BZ1-K123501x0y
    Radius BZ1 - LEL (Pentane), CO, H2S, O2, SO2    ✔    ✔   BZ1-K123501x1y
    Radius BZ1 - LEL (Pentane), CO, H2S, O2, SO2, PID       BZ1-K1235R0x0y
    Radius BZ1 - LEL (Pentane), CO, H2S, O2, SO2, PID      ✔   BZ1-K1235R0x1y
    Radius BZ1 - LEL (Pentane), CO, H2S, O2, SO2, PID    ✔     BZ1-K1235R1x0y
    Radius BZ1 - LEL (Pentane), CO, H2S, O2, SO2, PID    ✔    ✔   BZ1-K1235R1x1y
    x = Agency Certification: 1 = UL/CSA, 2 = ATEX/IECEx | y = Language: 1 = EN, 2 = FR, 3 = ES, 4 = DE
  1. Radius™ BZ1 Parts & Accessories

    18109431-AB Radius BZ1 Base (Without SafeCore)
    A = Approvals, where 1 = UL/CSA, 2=ATEX/IECEx
    B = Language, where 1 = English, 2 = French, 3 = Spanish, 4 = German
    18109388-1A Instrinsic Safety External Power Supply
    A = Power Cord, where 1 = North America, 2 = Europe, 3 = Australia, 4 = UK
    17156261 50 m Replacement Intrinsic Safety Cable
    17155932
    Intrinsic Safety Power Port Dust Cap
    18109444
    Speaker Grill
    18109445
    Speaker Dust Filter (Pack of 2)
    18109442
    Alarm Muffler (Pack of 2)
    17155923
    Charging Power Supply (Without Power Cord)
    17155000
    Power Cord (North America)
    17155003
    Power Cord (Europe)
    17155001
    Power Cord (Australia)
    17155005
    Power Cord (UK)
    18109498
    Calibration Cup and Tubing Kit
    17155934
    Charging Port Dust Cap
    18109448
    Boot
    17155915-A
    Printed Manual
    A = Language, where 1 = English, 2 = French, 3 = Spanish, 4 = German

    SafeCore™ Docking & Calibration Solutions

    18109396-ABC DSX Docking Station for SafeCore™
    A = Mode, where
    0 = Standalone mode,
    1 = Cloud-Connected mode,
    2 = Local Server mode
    B = Quantity of gas inlet ports,
    3 = 3-port,
    6 = 6-port
    C = Power Cord, where
    1 = North America, 2 = European, 3 = Australia, 4 = UK

    SafeCore™ parts & accessories

    17156650-1 Replacement Sensor, SafeCore, Carbon Monoxide (CO)
    17156650-2 Replacement Sensor, SafeCore, Hydrogen Sulfide (H2S)
    17156650-3 Replacement Sensor, SafeCore, Oxygen (O2)
    17156650-4 Replacement Sensor, SafeCore, Nitrogen Dioxide (NO2)
    17156650-5 Replacement Sensor, SafeCore, Sulfur Dioxide (SO2)
    17156650-6 Replacement Sensor, SafeCore, Ammonia (NH3)
    17156650-7 Replacement Sensor, SafeCore, Chlorine (Cl2)
    17156650-B Replacement Sensor, SafeCore, Hydrogen Cyanide (HCN)
    17156650-C Replacement Sensor, SafeCore, Hydrogen (H2)
    17156650-G Replacement Sensor, SafeCore, Carbon Monoxide / Hydrogen Low (CO / H2 LOW)
    17156650-H Replacement Sensor, SafeCore, Carbon Monoxide (CO) High
    17156650-J Replacement Sensor, SafeCore, Carbon Monoxide / Hydrogen Sulfide (CO/H2S)
    17156650-K Replacement Sensor, SafeCore, LEL, Pentane
    17156650-L Replacement Sensor, SafeCore, LEL, CH4
    17156650-R Replacement Sensor, SafeCore, PID (VOCs)
    18109472 DualSense Pack, SafeCore, Carbon Monoxide (CO)
    18109473 DualSense Pack, SafeCore, Hydrogen Sulfide (H2S)
    18109474 DualSense Pack, SafeCore, Oxygen (O2)
    18109475 DualSense Pack, SafeCore, Nitrogen Dioxide (NO2)
    18109476 DualSense Pack, SafeCore, Sulfur Dioxide (SO2)
    18109486 DualSense Pack, SafeCore, Carbon Monoxide / Hydrogen Low (CO / H2 LOW)
    18109488 DualSense Pack, SafeCore, Carbon Monoxide / Hydrogen Sulfide (CO/H2S)
    18109489 DualSense Pack, SafeCore, LEL, Pentane
    18109490 DualSense Pack, SafeCore, LEL, CH4
    17134701 Sensor Plug
    17156465 Backup Battery
    17155888 Sensor Collar
    18109446 Module Cover
    17156771 SafeCore Nameplate
    17156983 Hand Tool
    18109455 Pump Inlet Water Barrier (Pack of 3)
    18109447 Pump Bottom Dust Filter (Pack of 2)
  1. Instrument Warranty:

    Two-year warranty, including sensors and battery

    Клавиатура:

    Three buttons

    Data log:

    At least 3 months at 10-second intervals

    Event logging:

    60 alarm events

    ЗАЩИТА ОТ ВНЕШНИХ ВОЗДЕЙСТВИЙ:

    IP66

    Материал корпуса:

    Impact-resistant polycarbonate alloys

    Габаритные размеры:

    29 x 29 x 55 cm (11,5 x 11,5 x 21,5 in)

    Вес:

    7,5 kg (16,5 lb)

    Диапазон температуры:

    -20 °C to 55 °C (-4 °F to 131 °F)

    Диапазон влажности:

    15 %–95 % без конденсации (непрерывно)

    Дисплей/показания:

    11,2 cm (4,4 in) monochrome backlit graphical liquid crystal display (LCD)

    Источник питания/рабочий цикл:

    Rechargeable nickel-metal hydride (NiMH) battery pack

    7 days (168 hours) typical @ 20 ºC, without pump, with wireless

    3,5 days (84 hours) typical @ 20 ºC, with pump, with wireless

    30 days (720 hours) typical @ 20 ºC, electrochemical sensors
              only, without pump, with wireless

    ≤8 hour recharge time

    Аварийные сигналы:
    108 decibel (dB) at 1 m (3,3 ft) redundant audible alarms
     

    Redundant visual alarm LEDs (red and blue)

    Датчики:

    Up to 6 sensors (catalytic bead, photoionization detector, and electrochemical)

    Up to 7 simultaneous readings

    Pump:

    Optional integral pump, up to 30,48 m (100 ft) sample draw

    Поставляется с монитором:

    Calibration cup (without pump), sample tubing and pump inlet water barrier (with pump), product manual, hand tool, charging power supply and region-specific cord

    Диапазон измерений:

    Каталитический шарик 

    Горючие газы: 0–100 % нижнего предела взрывоопасной концентрации с шагом 1 % 

    Электрохимический 

    Ammonia (NH3): 0–500 промилле с шагом 1 ppm

    Carbon Monoxide (CO): 0-1 500 ppm in 1 ppm increments

    Carbon Monoxide (CO High Range):
                0–9 999 промилле с шагом 1 ppm

    Carbon Monoxide (CO/H2 Low): 
                0–1 000 промилле с шагом 1 ppm

    Carbon Monoxide/Hydrogen Sulfide:
                CO: 0–1 500 промилле с шагом 1 ppm

                H
    2S: 0–500 промилле с шагом 0,1 ppm

    Chlorine (CL2): 0-50 ppm in 0,1 ppm increments

    Hydrogen (H2): 0-2 000 ppm in 1 ppm increments

    Hydrogen Sulfide (H2S): 0–500 промилле с шагом 0,1 ppm

    Hydrogen Cyanide (HCN): 0-30 ppm in 0,1 ppm increments

    Nitrogen Dioxide (NO2): 0–150 промилле с шагом 0,1 ppm

    Oxygen (O2): 0–30 % объема с шагом 0,1 %

    Sulfur Dioxide (SO2): 0–150 промилле с шагом 0,1 ppm

    Фотоионизация 

    Volatile Organic Compounds (10,6 eV): 0–2 000 промилле с шагом 0,1 ppm  


    Wireless:

    Optional LENS™ Wireless, proprietary mesh network

    Frequency: ISM license-free band (2,405 - 2,480 GHz)

    Max Peers: 25 devices per network group
           10 independent, configurable network groups

    Range: 300 m (~1 000 ft) line of sight

    Encryption: AES-128

    For Wireless Certifications click here

    Certifications:

    INGRESS PROTECTION IP66

    ATEX: 

    Ex da ia IIC T4 Ga, Equipment Group
    and Category II 1G

    Китай, CPC: 

    Китай, CPC

    Китай, EX:

    Ex d ia IIC T1 Ga; Ex d ia IIC T4 Gb IR sensor

    CSA:

    Cl I, Div 1, G A-D, T4
    C22.2 No. 152 applies only to
    %LEL thermo-catalytic reading

    IECEx:

    Ex da ia IIC T4 Ga 

    INMETRO: 

    Ex da ia IIC T4 Ga;
    Ex db ia IIC T4 Gb IR sensor

    UL:

    Cl I, Div 1, Gr A-D, T4;
    Cl 1 Zone 0 AEx da ia IIC T4 Ga1 

    REFERENCE GUIDE LANGUAGE:

    English, French, Spanish, German


Powered By OneLink